x
Send Your Inquiry Today
Quick Quote
Hydraulic oil filter for industrial filtration system banner

Hydraulic Filters & Oil Filtration Solutions

High-Efficiency Contamination Control for Demanding Hydraulic Systems

  • Cleaning oil with longer system life
  • Safer suction for pump protection
  • Faster filter replacement and maintenance
  • Reduce pollution in oil tanks
ISO 9001 quality system icon for Adiffer hydraulic products
ISO 9001 Quality System
Standardized control from production to inspection.
CE conformity documentation icon for Adiffer hydraulic products
CE Conformity Documentation
Documents available for applicable products and components.
REACH material compliance icon for Adiffer hydraulic products
REACH Material Compliance
Material reports support export compliance review.
  • Adiffer RF Type Return Line Filter for tank mounted hydraulic oil filtration
  • Adiffer RFA Type Mini Return Line Filter for compact hydraulic filtration systems
  • Adiffer RFB Type Magnetic Return Line Filter with check valve for hydraulic systems
  • Adiffer JL Type Suction Strainer for hydraulic pump inlet protection
  • Adiffer SP Type High Pressure Filter for hydraulic line filtration 10 and 25 micron
  • Adiffer AB Type Breather Filter and Filler Breather for hydraulic oil tanks
  • Adiffer RF Type Return Line Filter for tank mounted hydraulic oil filtration
  • Adiffer RFA Type Mini Return Line Filter for compact hydraulic filtration systems
  • Adiffer RFB Type Magnetic Return Line Filter with check valve for hydraulic systems
  • Adiffer JL Type Suction Strainer for hydraulic pump inlet protection
  • Adiffer SP Type High Pressure Filter for hydraulic line filtration 10 and 25 micron
  • Adiffer AB Type Breather Filter and Filler Breather for hydraulic oil tanks

Hydraulic Filter Technical Specifications

Series Basic Models Flow / Size Range Filtration
Return Line Filters (RF, RFA, RFB Series)
RF Series RF-60 to RF-1300 60–1300 L/min | Dia. 20–100 mm 1 / 3 / 5 / 10 / 20 / 30 μm
RFA Series RFA-25 to RFA-1000 25–1000 L/min | Dia. 15–90 mm 1 / 3 / 5 / 10 / 20 / 30 μm
RFB Series RFB-25 to RFB-1300 25–1300 L/min | Connecting tube optional 1 / 3 / 5 / 10 / 20 / 30 μm
Suction Strainers & Inlet Filters (JL Series)
JL Series JL-02 to JL-32 PT 1/4″–4″ | 25–900 L/min 100 mesh
Spin-On Filters & Line Elements (SP, SPA, SPB Series)
SP / SPA / SPB Series SP-06 to SPB-10 R3/4 / R1 / R1-1/4 10 / 25 μm
Filler Breathers & Tank Air Filters (AB Series)
AB Series AB-1162 / AB-1163 Hole 30 / 87 mm 50 mesh

Hydraulic Filter Types & Series

Find the right hydraulic filter series for cleaner oil flow and system protection.

Adiffer RF Type Return Line Filter for tank mounted hydraulic oil filtration

RF, RFA and RFB return line filters help remove particulate contamination from hydraulic oil before it returns to the tank. They are suitable for hydraulic power units, industrial machinery and other return-line filtration systems.
25–1300 L/min | 1–30 μm | 1–1.6 MPa

Adiffer JL Type Suction Strainer for hydraulic pump inlet protection

JL suction strainers are installed at the pump inlet to help prevent larger particles from entering the hydraulic pump. They support cleaner oil intake and are suitable for hydraulic tanks, compact hydraulic systems and industrial equipment.
PT 1/4″–4″ | 25–900 L/min | 100 mesh

Adiffer SP Type High Pressure Filter for hydraulic line filtration 10 and 25 micron

SP, SPA and SPB spin-on line filters use replaceable elements for convenient hydraulic oil filtration and maintenance. They are suitable for low-pressure return and suction circuits where quick element replacement and easier servicing are required.
SP-06~10 | 10/25μm | R3/4~R1-1/4

Adiffer AB Type Breather Filter and Filler Breather for hydraulic oil tanks

AB filler breathers help filter incoming air and protect the filling port of hydraulic tanks. They help reduce dust and other external contaminants entering hydraulic power units and industrial tanks during filling and normal tank breathing.
AB-1162/1163 | hole 30/87 mm | 50 mesh

Note: We also provide 100% interchangeable replacement filter elements for our series and major global brands (Hydac, Parker, Rexroth, etc.)—simply send us your OEM part number or dimensions for a quick quote.

Need a Better Hydraulic Oil Filter?

Hydraulic filters help control oil contamination through return lines, suction circuits, pressure lines and tanks. For example, Return Line Filters support cleaner oil return, and the Suction Strainers protect the inlet of the pump. In addition, High Pressure Filters support local line filtration, and the Filler Breathers reduce dust during tank breathing and oil filling.

Adiffer supports practical hydraulic filter matching before quotation. Our team helps check flow, filtration accuracy, port size, hole size, filter element model and replacement requirements. Therefore, OEM buyers, distributors and maintenance teams can reduce the risk of misfits and improve hydraulic system protection.

Read More

Hydraulic Filtration for Cleaner Oil & System Protection

Multi-point pollution control :
RF, JL, SP and AB series protect oil return, pump inlet, pipeline and tank breathing.
Cleaner hydraulic oil flow :
Filters reduce particles before affecting the pumps, hydraulic valves and oil circuits.
Lower error part risk :
Matching filters help avoid incorrect flow rate, ports, filter ratings, or element selections.
Easier maintenance :
Replaceable elements and blocking indicators simplify the service to industrial systems.
Reduced downtime :
Clean oil and appropriate filter replacement can minimize maintenance delays and accidental parking.
Hydraulic filter housings in Adiffer Hydraulics production workshop
Industrial hydraulic filtration system skid for oil filtration

Return Line Filter, Cleaner Return Oil

Tank-Mounted Return Filtration :
RF oil return line is filtered before the clean oil flows back to the reservoir.
Wide Flow Range :
60—1300 L/min models support compact power units and large industrial oil systems.
Multiple Filtering Ratings :
1 / 3 / 5 / 10 / 20 / 30 μm options match different oil cleanliness requirements.
Optional Blockage Indicator :
When the return filter needs to be replaced, the Y/C indicator option reminds the user.
Practical Replacement Matching :
RF filter components support OEM, repair and reseller replacement orders.

Cleaning Oil Protection Starts With The Right Filter

Different hydraulic filters and filtration products help to protect pumps, valves, and oil lines, including return line filters, suction filters, spin-on filters, and filler respirators.

Hydraulic filter wide flow range icon
Wide Flow Range

60-1300 L / min covers both compact and large hydraulic systems.

Hydraulic filter filtration rating icon
Precision Filter Rating

1-30 μm option helps to maintain the cleanliness of the hydraulic oil.

Replaceable hydraulic filter element icon
Replaceable Filter Element

Quick change components simplify maintenance, repair and distributor inventory.

Hydraulic filter clogging indicator icon
Optional Blocking Indicator

Y/C indicator reminds the user to replace the component.

ADIFFER

Hydraulic Filter Catalogs & Resources

Download hydraulic product technical documents
Hydraulic Filters Catalog

Download Hydraulic Filters Technology PDFs here.

Download hydraulic product technical documents
Hydraulic Accessories Catalog

Download hydraulic accessories and supporting component information.

Download hydraulic product technical documents
Popular Products Catalog

Quick reference guide for popular hydraulic pumps, valves, motors and hydraulic filters.

Why Choose Adiffer for Hydraulic Filters

Adiffer hydraulic filter manufacturing workshop with CNC machining equipment
CNC machining process for hydraulic filter components at Adiffer
  • 35 Years of Factory & Export Experience:Hydraulic component manufacturing and export support.
  • Multiple Hydraulic Filter Series: RF/RFA/RFB return filters, JL suction strainers, SP/SPA/SPB spin-on filters, and AB filler breathers are available for different hydraulic filtration needs.
  • Global Supply Support: We support international buyers with quotation, model confirmation, packing, and export delivery.
  • Replacement & Model Matching Support: Send us your OEM part number, filter model, dimensions, or photos for replacement filter matching and quotation.
  • One-Stop Procurement: We provide complete hydraulic solutions. Buy your valves, pumps, motors, and parts all in one place.
Applications

Hydraulic Filters for Industrial Applications

Adiffer hydraulic filters help maintain oil cleanliness and protect hydraulic components in industrial and mobile hydraulic systems.

Plastic injection molding machine with hydraulic filtration system
Injection mold hydraulic system

In plastic injection molding machines and die casting equipment, hydraulic oil cleanliness affects clamping pressure, injection movement and valve response. RFA-160 and RFA-250 return line filters help clean return oil before it flows back to compact reservoirs. In addition, SP-10×10 spin-on line filters support local circuit filtration where easier filter element replacement is required. AB-1162 filler breathers reduce dust entry during oil filling and tank breathing, supporting cleaner factory hydraulic filtration maintenance.

Marine deck winch hydraulic system with oil filtration
Ship deck and offshore hydraulic equipment

Marine deck machinery, offshore winches and shipboard hydraulic systems often work in humid, dusty and long-duty environments. RF-330 and RF-500 return line filters support hydraulic oil filtration for medium and large return circuits. Meanwhile, JL-16 or JL-20 suction strainers help protect pump inlets before oil enters the hydraulic pump. For systems with possible metal particles during long service, RFB-250 or RFB-400 magnetic return line filters add return oil filtration with magnetic contamination capture.

Get An Instant Quote
Quick Quote
hydraulic accessories including gauges filters and bell housings displayed on an industrial workbench

Hydraulic Filters & Replacement Support from Adiffer

Adiffer supplies hydraulic filters for OEM, maintenance and replacement applications. Our range includes RF/RFA/RFB return line filters, JL suction strainers, SP/SPA/SPB spin-on filters and AB filler breathers, with model matching and replacement support for hydraulic systems. For replacement selection, review our hydraulic filter elements and confirm the filter series, complete element code, dimensions, filtration rating, seal material, fluid, and operating conditions.

Extended Hydraulic Filter Series Reference

Final selection should be confirmed by model code, flow rate, filtration rating, port or mounting size, operating pressure, element model and application requirements.

RF Series

Model Flow Rate Filtration Rated Pressure / ΔP Element Model
RF-60×* 60 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0060R*BN/HC
RF-110×* 110 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0110R*BN/HC
RF-160×* 160 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0160R*BN/HC
RF-240×* 240 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0240R*BN/HC
RF-330×* 330 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0330R*BN/HC
RF-500×* 500 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0500R*BN/HC
RF-660×* 660 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0660R*BN/HC
RF-850×* 850 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0850R*BN/HC
RF-950×* 950 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF0950R*BN/HC
RF-1300×* 1300 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1 MPa / ≤0.07 MPa / 0.35 MPa JF1300R*BN/HC

RFA Series

Model Flow Rate Filtration Rated Pressure / ΔP Element Model
RFA-25×*L 25 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-25×*
RFA-40×*L 40 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-40×*
RFA-63×*L 63 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-63×*
RFA-100×*L 100 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-100×*
RFA-160×*L 160 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-160×*
RFA-250×*F 250 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-250×*
RFA-400×*F 400 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-400×*
RFA-630×*F 630 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-630×*
RFA-800×*F 800 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-800×*
RFA-1000×*F 1000 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FAX-1000×*

RFB Series

Model Flow Rate Filtration Rated Pressure / ΔP Element Model
RFB-25×* 25 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-25×*
RFB-40×* 40 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-40×*
RFB-63×* 63 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-63×*
RFB-100×* 100 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-100×*
RFB-160×* 160 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-160×*
RFB-250×* 250 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-250×*
RFB-400×* 400 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-400×*
RFB-630×* 630 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-630×*
RFB-800×* 800 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-800×*
RFB-1000×* 1000 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-1000×*
RFB-1300×* 1300 L/min 1 / 3 / 5 / 10 / 20 / 30 μm 1.6 MPa / ≤0.075 MPa / 0.35 MPa FBX-1300×*

JL Series

Model Port Flow Rate Filtration Main Dimensions
JL-02 PT 1/4″ 25 L/min 100 mesh B55 / C82 / D90 mm
JL-03 PT 3/8″ 25 L/min 100 mesh B55 / C82 / D90 mm
JL-04 PT 1/2″ 35 L/min 100 mesh B66 / C82 / D90 mm
JL-06 PT 3/4″ 60 L/min 100 mesh B66 / C122 / D132 mm
JL-08 PT 1″ 110 L/min 100 mesh B66 / C142 / D152 mm
JL-10 PT 1-1/4″ 210 L/min 100 mesh B66 / C162 / D176 mm
JL-12 PT 1-1/2″ 260 L/min 100 mesh B82 / C182 / D196 mm
JL-16 PT 2″ 390 L/min 100 mesh B103 / C182 / D197 mm
JL-20 PT 2-1/2″ 600 L/min 100 mesh B115 / C232 / D135 mm
JL-24 PT 3″ 700 L/min 100 mesh B135 / C232 / D235 mm
JL-32 PT 4″ 900 L/min 100 mesh B158 / C250 / D270 mm

SP / SPA / SPB Series

Model Return Flow Suction Flow Filtration Port / Element Model
SP-06×10 60 L/min 20 L/min 10 μm R3/4 / SPX-06×10
SP-06×25 70 L/min 25 L/min 25 μm R3/4 / SPX-06×25
SP-08×10 60 L/min 20 L/min 10 μm R1 / SPX-08×10
SP-08×25 70 L/min 25 L/min 25 μm R1 / SPX-08×25
SP-10×10 144 L/min 42 L/min 10 μm R1-1/4 / SPX-10×10
SP-10×25 160 L/min 50 L/min 25 μm R1-1/4 / SPX-10×25
SPA-10×10 200 L/min 58 L/min 10 μm R1-1/4 / SPAX-10×10
SPB-10×10 320 L/min 80 L/min 10 μm R1-1/4 / SPBX-10×10

Operating Data: Max. operating pressure: 0.7 MPa | Burst pressure: 2.0 MPa | Bypass setting: 0.25 MPa | Temperature range: -30°C to 90°C

AB Series

Model Hole Size Filtration Main Dimensions Weight
AB-1162 30 mm 50 mesh A54 / B31 / C31 / D68 / E99 / F45.5 / G57 mm 0.08 kg
AB-1163 87 mm 50 mesh A81 / B48 / C47 / D90 / E132 / F71 / G99 mm 0.21 kg

Testimonials

  • We ordered the Adiffer hydraulic filter for a power plant maintenance project. The return oil circuit filter element and the hydraulic oil filter element match clearly, and the team helps to confirm the flow rate and filtration accuracy before the quotation. It provides good support for industrial filtration replacement.

    Customer testimonial profile photo from Italy
    Luca Bianchi
    Italy

Hydraulic Filtration Technology FAQs

How do I confirm the correct filter position in a hydraulic circuit?

Check whether the filter is installed on the return line, the suction side, the pressure line or the tank breathing port. Each location has different flow, pressure and pollution control requirements. Loop filters, suction filters, rotary filters and filler respirators should not be selected solely on the basis of appearance.

What pressure drop data should be checked before filter replacement?

For return line filters, the buyer should check the working pressure, initial pressure drop and maximum allowable pressure drop. A lower initial ΔP helps to maintain a stable oil return, and the maximum ΔP occurs when the filter element may need to be replaced. Ignoring the pressure drop will cause poor oil circulation.

How should filtration accuracy be selected for different hydraulic systems?

The filtration accuracy should be matched with the component sensitivity, oil cleanliness target and circuit position. Servo valves, proportional valves and compact hydraulic power units often require cleaner hydraulic oil than the basic circuit. Choosing too fine filter may increase the pressure drop ; choosing too coarse may leave harmful particles.

When should a clogging indicator be added to a return line filter?

The clogging indicator is useful when the system is running continuously, the reservoir is difficult to check, or the maintenance interval must be controlled. In industrial hydraulic systems, OEM equipment and maintenance projects, the Y / C indicator option helps operators to monitor filter clogging and reduce delays in replacement.

If the suction filter is not properly selected, it will cause pump cavitation?

Yes. Too small, too dense or poorly maintained filter will increase the inlet resistance. This may cause noise, cavitation, unstable flow and early damage of the pump. For suction surface protection, port size, flow and grid rating must be carefully checked.

What should be checked when replacing the hydraulic oil filter?

Determine the filter element type, filter loss, length, seal type, flow direction and shell compatibility. Hydraulic oil filter elements with similar appearance may have different media, collapse strength or micron level. For B2B replacement orders, photos, old code, and application details help reduce the risk of mismatches.

Why does a stuffed respirator work in a closed hydraulic tank?

When the oil level changes during the movement of the cylinder or the operation of the system, the hydraulic tank still needs to exchange air. The filler respirator helps to reduce dust entry during breathing and oil filling. If there is no proper tank breathing protection, air pollutants will enter the tank, affecting the cleanliness of hydraulic oil.

How to evaluate whether a SP spin filter is suitable for my circuit?

Check whether the return oil flow or the suction oil flow is used in the circuit, and then confirm the thread connection, the filtration grade, the bypass setting, and the spin-on component model. The SP filter should be selected according to the circuit function and maintenance needs, and should not be selected only according to the thread size or shell shape.

What information helps Adiffer confirm a filter replacement faster?

Send the old filter model, filter element code, photos, port or hole size, flow, filtering accuracy, installation location and working medium. For unclear models, provide tank layout or piping photos. This helps Adiffer check hydraulic filter matching prior to OEM, repair and distributor order quotes. After preparing these details, contact our team for model matching and quotation support.

One-Stop Hydraulic Components Manufacturing Expert

Scroll to Top