Hydraulic Filter Technical Specifications
| Series | Basic Models | Flow / Size Range | Filtration |
|---|---|---|---|
| Return Line Filters (RF, RFA, RFB Series) | |||
| RF Series | RF-60 to RF-1300 | 60–1300 L/min | Dia. 20–100 mm | 1 / 3 / 5 / 10 / 20 / 30 μm |
| RFA Series | RFA-25 to RFA-1000 | 25–1000 L/min | Dia. 15–90 mm | 1 / 3 / 5 / 10 / 20 / 30 μm |
| RFB Series | RFB-25 to RFB-1300 | 25–1300 L/min | Connecting tube optional | 1 / 3 / 5 / 10 / 20 / 30 μm |
| Suction Strainers & Inlet Filters (JL Series) | |||
| JL Series | JL-02 to JL-32 | PT 1/4″–4″ | 25–900 L/min | 100 mesh |
| Spin-On Filters & Line Elements (SP, SPA, SPB Series) | |||
| SP / SPA / SPB Series | SP-06 to SPB-10 | R3/4 / R1 / R1-1/4 | 10 / 25 μm |
| Filler Breathers & Tank Air Filters (AB Series) | |||
| AB Series | AB-1162 / AB-1163 | Hole 30 / 87 mm | 50 mesh |
Hydraulic Filter Types & Series
Find the right hydraulic filter series for cleaner oil flow and system protection.
RF, RFA and RFB return line filters help remove particulate contamination from hydraulic oil before it returns to the tank. They are suitable for hydraulic power units, industrial machinery and other return-line filtration systems.
25–1300 L/min | 1–30 μm | 1–1.6 MPa
JL suction strainers are installed at the pump inlet to help prevent larger particles from entering the hydraulic pump. They support cleaner oil intake and are suitable for hydraulic tanks, compact hydraulic systems and industrial equipment.
PT 1/4″–4″ | 25–900 L/min | 100 mesh
SP, SPA and SPB spin-on line filters use replaceable elements for convenient hydraulic oil filtration and maintenance. They are suitable for low-pressure return and suction circuits where quick element replacement and easier servicing are required.
SP-06~10 | 10/25μm | R3/4~R1-1/4
AB filler breathers help filter incoming air and protect the filling port of hydraulic tanks. They help reduce dust and other external contaminants entering hydraulic power units and industrial tanks during filling and normal tank breathing.
AB-1162/1163 | hole 30/87 mm | 50 mesh
Note: We also provide 100% interchangeable replacement filter elements for our series and major global brands (Hydac, Parker, Rexroth, etc.)—simply send us your OEM part number or dimensions for a quick quote.
Need a Better Hydraulic Oil Filter?
Hydraulic filters help control oil contamination through return lines, suction circuits, pressure lines and tanks. For example, Return Line Filters support cleaner oil return, and the Suction Strainers protect the inlet of the pump. In addition, High Pressure Filters support local line filtration, and the Filler Breathers reduce dust during tank breathing and oil filling.
Adiffer supports practical hydraulic filter matching before quotation. Our team helps check flow, filtration accuracy, port size, hole size, filter element model and replacement requirements. Therefore, OEM buyers, distributors and maintenance teams can reduce the risk of misfits and improve hydraulic system protection.
Hydraulic Filtration for Cleaner Oil & System Protection
RF, JL, SP and AB series protect oil return, pump inlet, pipeline and tank breathing.
Filters reduce particles before affecting the pumps, hydraulic valves and oil circuits.
Matching filters help avoid incorrect flow rate, ports, filter ratings, or element selections.
Replaceable elements and blocking indicators simplify the service to industrial systems.
Clean oil and appropriate filter replacement can minimize maintenance delays and accidental parking.


Return Line Filter, Cleaner Return Oil
RF oil return line is filtered before the clean oil flows back to the reservoir.
60—1300 L/min models support compact power units and large industrial oil systems.
1 / 3 / 5 / 10 / 20 / 30 μm options match different oil cleanliness requirements.
When the return filter needs to be replaced, the Y/C indicator option reminds the user.
RF filter components support OEM, repair and reseller replacement orders.
Cleaning Oil Protection Starts With The Right Filter
Different hydraulic filters and filtration products help to protect pumps, valves, and oil lines, including return line filters, suction filters, spin-on filters, and filler respirators.
60-1300 L / min covers both compact and large hydraulic systems.
1-30 μm option helps to maintain the cleanliness of the hydraulic oil.
Quick change components simplify maintenance, repair and distributor inventory.
Y/C indicator reminds the user to replace the component.
Hydraulic Filter Catalogs & Resources
Download hydraulic accessories and supporting component information.
Quick reference guide for popular hydraulic pumps, valves, motors and hydraulic filters.
Why Choose Adiffer for Hydraulic Filters


- 35 Years of Factory & Export Experience:Hydraulic component manufacturing and export support.
- Multiple Hydraulic Filter Series: RF/RFA/RFB return filters, JL suction strainers, SP/SPA/SPB spin-on filters, and AB filler breathers are available for different hydraulic filtration needs.
- Global Supply Support: We support international buyers with quotation, model confirmation, packing, and export delivery.
- Replacement & Model Matching Support: Send us your OEM part number, filter model, dimensions, or photos for replacement filter matching and quotation.
- One-Stop Procurement: We provide complete hydraulic solutions. Buy your valves, pumps, motors, and parts all in one place.
Hydraulic Filters for Industrial Applications
Adiffer hydraulic filters help maintain oil cleanliness and protect hydraulic components in industrial and mobile hydraulic systems.

In plastic injection molding machines and die casting equipment, hydraulic oil cleanliness affects clamping pressure, injection movement and valve response. RFA-160 and RFA-250 return line filters help clean return oil before it flows back to compact reservoirs. In addition, SP-10×10 spin-on line filters support local circuit filtration where easier filter element replacement is required. AB-1162 filler breathers reduce dust entry during oil filling and tank breathing, supporting cleaner factory hydraulic filtration maintenance.

Marine deck machinery, offshore winches and shipboard hydraulic systems often work in humid, dusty and long-duty environments. RF-330 and RF-500 return line filters support hydraulic oil filtration for medium and large return circuits. Meanwhile, JL-16 or JL-20 suction strainers help protect pump inlets before oil enters the hydraulic pump. For systems with possible metal particles during long service, RFB-250 or RFB-400 magnetic return line filters add return oil filtration with magnetic contamination capture.
Extended Hydraulic Filter Series Reference
Final selection should be confirmed by model code, flow rate, filtration rating, port or mounting size, operating pressure, element model and application requirements.
- Return Line Filters
- Suction Strainers
- Spin-On Filters
- Filler Breathers
RF Series
| Model | Flow Rate | Filtration | Rated Pressure / ΔP | Element Model |
|---|---|---|---|---|
| RF-60×* | 60 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0060R*BN/HC |
| RF-110×* | 110 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0110R*BN/HC |
| RF-160×* | 160 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0160R*BN/HC |
| RF-240×* | 240 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0240R*BN/HC |
| RF-330×* | 330 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0330R*BN/HC |
| RF-500×* | 500 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0500R*BN/HC |
| RF-660×* | 660 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0660R*BN/HC |
| RF-850×* | 850 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0850R*BN/HC |
| RF-950×* | 950 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF0950R*BN/HC |
| RF-1300×* | 1300 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1 MPa / ≤0.07 MPa / 0.35 MPa | JF1300R*BN/HC |
RFA Series
| Model | Flow Rate | Filtration | Rated Pressure / ΔP | Element Model |
|---|---|---|---|---|
| RFA-25×*L | 25 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-25×* |
| RFA-40×*L | 40 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-40×* |
| RFA-63×*L | 63 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-63×* |
| RFA-100×*L | 100 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-100×* |
| RFA-160×*L | 160 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-160×* |
| RFA-250×*F | 250 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-250×* |
| RFA-400×*F | 400 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-400×* |
| RFA-630×*F | 630 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-630×* |
| RFA-800×*F | 800 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-800×* |
| RFA-1000×*F | 1000 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FAX-1000×* |
RFB Series
| Model | Flow Rate | Filtration | Rated Pressure / ΔP | Element Model |
|---|---|---|---|---|
| RFB-25×* | 25 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-25×* |
| RFB-40×* | 40 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-40×* |
| RFB-63×* | 63 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-63×* |
| RFB-100×* | 100 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-100×* |
| RFB-160×* | 160 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-160×* |
| RFB-250×* | 250 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-250×* |
| RFB-400×* | 400 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-400×* |
| RFB-630×* | 630 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-630×* |
| RFB-800×* | 800 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-800×* |
| RFB-1000×* | 1000 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-1000×* |
| RFB-1300×* | 1300 L/min | 1 / 3 / 5 / 10 / 20 / 30 μm | 1.6 MPa / ≤0.075 MPa / 0.35 MPa | FBX-1300×* |
JL Series
| Model | Port | Flow Rate | Filtration | Main Dimensions |
|---|---|---|---|---|
| JL-02 | PT 1/4″ | 25 L/min | 100 mesh | B55 / C82 / D90 mm |
| JL-03 | PT 3/8″ | 25 L/min | 100 mesh | B55 / C82 / D90 mm |
| JL-04 | PT 1/2″ | 35 L/min | 100 mesh | B66 / C82 / D90 mm |
| JL-06 | PT 3/4″ | 60 L/min | 100 mesh | B66 / C122 / D132 mm |
| JL-08 | PT 1″ | 110 L/min | 100 mesh | B66 / C142 / D152 mm |
| JL-10 | PT 1-1/4″ | 210 L/min | 100 mesh | B66 / C162 / D176 mm |
| JL-12 | PT 1-1/2″ | 260 L/min | 100 mesh | B82 / C182 / D196 mm |
| JL-16 | PT 2″ | 390 L/min | 100 mesh | B103 / C182 / D197 mm |
| JL-20 | PT 2-1/2″ | 600 L/min | 100 mesh | B115 / C232 / D135 mm |
| JL-24 | PT 3″ | 700 L/min | 100 mesh | B135 / C232 / D235 mm |
| JL-32 | PT 4″ | 900 L/min | 100 mesh | B158 / C250 / D270 mm |
SP / SPA / SPB Series
| Model | Return Flow | Suction Flow | Filtration | Port / Element Model |
|---|---|---|---|---|
| SP-06×10 | 60 L/min | 20 L/min | 10 μm | R3/4 / SPX-06×10 |
| SP-06×25 | 70 L/min | 25 L/min | 25 μm | R3/4 / SPX-06×25 |
| SP-08×10 | 60 L/min | 20 L/min | 10 μm | R1 / SPX-08×10 |
| SP-08×25 | 70 L/min | 25 L/min | 25 μm | R1 / SPX-08×25 |
| SP-10×10 | 144 L/min | 42 L/min | 10 μm | R1-1/4 / SPX-10×10 |
| SP-10×25 | 160 L/min | 50 L/min | 25 μm | R1-1/4 / SPX-10×25 |
| SPA-10×10 | 200 L/min | 58 L/min | 10 μm | R1-1/4 / SPAX-10×10 |
| SPB-10×10 | 320 L/min | 80 L/min | 10 μm | R1-1/4 / SPBX-10×10 |
Operating Data: Max. operating pressure: 0.7 MPa | Burst pressure: 2.0 MPa | Bypass setting: 0.25 MPa | Temperature range: -30°C to 90°C
AB Series
| Model | Hole Size | Filtration | Main Dimensions | Weight |
|---|---|---|---|---|
| AB-1162 | 30 mm | 50 mesh | A54 / B31 / C31 / D68 / E99 / F45.5 / G57 mm | 0.08 kg |
| AB-1163 | 87 mm | 50 mesh | A81 / B48 / C47 / D90 / E132 / F71 / G99 mm | 0.21 kg |
Testimonials
Hydraulic Filtration Technology FAQs
Check whether the filter is installed on the return line, the suction side, the pressure line or the tank breathing port. Each location has different flow, pressure and pollution control requirements. Loop filters, suction filters, rotary filters and filler respirators should not be selected solely on the basis of appearance.
For return line filters, the buyer should check the working pressure, initial pressure drop and maximum allowable pressure drop. A lower initial ΔP helps to maintain a stable oil return, and the maximum ΔP occurs when the filter element may need to be replaced. Ignoring the pressure drop will cause poor oil circulation.
The filtration accuracy should be matched with the component sensitivity, oil cleanliness target and circuit position. Servo valves, proportional valves and compact hydraulic power units often require cleaner hydraulic oil than the basic circuit. Choosing too fine filter may increase the pressure drop ; choosing too coarse may leave harmful particles.
The clogging indicator is useful when the system is running continuously, the reservoir is difficult to check, or the maintenance interval must be controlled. In industrial hydraulic systems, OEM equipment and maintenance projects, the Y / C indicator option helps operators to monitor filter clogging and reduce delays in replacement.
Yes. Too small, too dense or poorly maintained filter will increase the inlet resistance. This may cause noise, cavitation, unstable flow and early damage of the pump. For suction surface protection, port size, flow and grid rating must be carefully checked.
Determine the filter element type, filter loss, length, seal type, flow direction and shell compatibility. Hydraulic oil filter elements with similar appearance may have different media, collapse strength or micron level. For B2B replacement orders, photos, old code, and application details help reduce the risk of mismatches.
When the oil level changes during the movement of the cylinder or the operation of the system, the hydraulic tank still needs to exchange air. The filler respirator helps to reduce dust entry during breathing and oil filling. If there is no proper tank breathing protection, air pollutants will enter the tank, affecting the cleanliness of hydraulic oil.
Check whether the return oil flow or the suction oil flow is used in the circuit, and then confirm the thread connection, the filtration grade, the bypass setting, and the spin-on component model. The SP filter should be selected according to the circuit function and maintenance needs, and should not be selected only according to the thread size or shell shape.
Send the old filter model, filter element code, photos, port or hole size, flow, filtering accuracy, installation location and working medium. For unclear models, provide tank layout or piping photos. This helps Adiffer check hydraulic filter matching prior to OEM, repair and distributor order quotes. After preparing these details, contact our team for model matching and quotation support.